Industrial Node

Specification

Vibration
  • Acceleration Measurement on 3 - axis, Axial,Horizontal and Radial
  • Dynamic range +/- 4G (configurable to 2, 4, 8 or 16)
  • Frequency range 10 to 1000Hz
  • Sampling rate 6600Hz
  • Resolution 16-bit
  • FFT resolution 1Hz/ bin
Temperature
  • Measurement range - 40°C to +85 °C
  • Resolution 0.1°C
  • Accuracy +/- 2°C (mounting dependent)
  • Repeatability +/- 0.1°C
Wireless communication
  • 2.4GHz
Battery
  • 3.6V lithium thionyl chloride
  • Battery lifetime est. 3 years (Battery life is dependent on operating temperature and configuration)
Dimensions
  • 78.5 x 28 mm
  • Mounting to M8 thread
  • Weight 129g
  • Top cap material PE HD
Environment
  • Operating -40°C to +85 °C
  • Storage 30 °C maximum
  • IP68 (dust-tight and resistant to water up to 1m)
Atex
  • ATEX II 2 G Ex ib IIC T4 Zone 1 & 2
  • -40°C 5 Ta 5 +60°C
Software
  • Fully configurable data delivery and integration to major clouds
  • Customer cloud application
  • Device management